At a glance
- Zero-speed and drive monitoring
- 4 safe semiconductor outputs
- PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (EN 62061)
- Maximum input frequency of 2 kHz
- Adjustable monitoring limit/monitoring frequency from 0.1 to 9.9 Hz or 0.5 to 99 Hz
- 2 application diagnostic outputs for failure and status display
- Diagnostic LEDs
Your Benefits
- Easy commissioning – using only a screwdriver – reduces installation time
- Tool backup using the Flexi Soft Designer and the Flexi Classic Configurator
- Additional HTL encoder evaluation
- Cascading of units is possible
Technical data overview
Safety integrity level |
SIL3 (IEC 61508) SILCL3 (EN 62061) |
Category | Category 4 (EN ISO 13849) |
Performance level | PL e (EN ISO 13849) |
Configuration method | Via rotary switch |
Drive safety functions |
Standstill Safe speed monitoring (SSM) Safely-limited speed (SLS) |
Encoder interface |
Proxy A/B incremental encoder, HTL |