- Safety relays for monitoring ESPE and safety switches
- Up to PL e (EN ISO 13849), SIL3 (IEC 61508)
- 2 safety outputs, fast response time of 10 ms
- Slim housing
- Plug-in terminals
- Diagnostics via status LEDs and application diagnostic outputs
- Short safety distances owing to fast response times for compact machines and a high level of productivity
- Short maintenance times and low maintenance costs during module replacement thanks to plug-in terminals and the simple method of removing the safety relay from the mounting rail
- More space available in the control cabinet thanks to the slim housing
- Intuitive troubleshooting due to versatile diagnostics interfaces
- Easy wiring and installation – only one connection diagram required per module
Technical Data Overview
Applications | Output expansion module for OSSDs / evaluation unit |
Safety integrity level |
SIL3 (IEC 61508) SILCL3 (IEC 62061) |
Category | Category 4 (EN ISO 13849) |
Performance level | PL e (EN ISO 13849) |
Sensor monitoring |
Discrepancy monitoring Sequence monitoring Cross-circuit detection |
Typical response time | 10ms |
Number of enable current contacts | 2 |
Housing width | 18mm |